Sundyne is a US manufacturer of centrifugal pumps and compressors for chemical, refining, petrochemical and power plants. The headquarters is in Arvada (Colorado, USA). Since 2025 the company has been part of Honeywell. Steiner Ukraine is the official representative of Sundyne in Ukraine: we select pumps for the process conditions, supply equipment and spare parts, and provide service.
The product lines differ in drive type, shaft sealing method and the standard they are built to.
| The | Design | Standard | Typical duty |
|---|---|---|---|
| Sundyne Direct Drive | vertical overhung pump with direct drive | API 610 (OH3, OH5); LMV-801S — API 685 | low flow, head up to 314 m |
| Sundyne Integrally Geared | single-stage pump with integral gearbox | API 610 (OH6) | low flow, head up to 1,921 m |
| Multistage Sundyne HMP | several stages on one gearbox | API 610 / ISO 13709 | head up to 4,420 m |
| ANSIMAG | non-metallic sealless magnetic drive pump, ETFE lined | ASME B73.3, ISO 2858 | acids, alkalis, solvents up to 121 °C |
| HMD Kontro | metallic sealless magnetic drive pump | API 685, ASME B73.3, ISO 2858 | toxic, flammable, hot liquids up to 450 °C |
In Sundyne Integrally Geared pumps the motor drives the input shaft of a speed-increasing gearbox. The gearbox raises the speed, so the impeller on the high-speed shaft turns much faster than the motor.
The head of a centrifugal impeller rises with rotational speed. As a result, one impeller delivers the head that a conventional pump needs several stages to reach.
The hydraulics are matched to the specific duty point by combining the impeller, diffuser and inducer (a screw-type wheel at the inlet). This sets the efficiency, curve shape and required net positive suction head (NPSH). Why NPSH matters is explained in the article “Pump cavitation: symptoms, causes and how to eliminate it”.
ANSIMAG and HMD Kontro pumps and the LMV-801S model have no mechanical shaft seal. Torque from the motor is transmitted through a magnetic coupling. The outer magnet rotor turns outside the casing, the inner one in the pumped liquid. A sealed containment shell separates them.
The liquid stays entirely inside the casing. There is no seal to wear and no seal support system.
The main risks for this type of pump are dry running, low-flow operation and magnet decoupling. A power monitor in the motor control centre protects against them: it tracks power consumption and trips when it leaves the set limits. For additional protection, the pump can be fitted with secondary containment in case the containment shell is damaged.
How seals for aggressive media differ is described in the article “How seals differ for pumps handling aggressive liquids”.
Thanks to unified dimensions, a mechanically sealed pump can be replaced with a sealless one without changing the piping or baseplate.
Sundyne publishes performance data separately for 60 Hz (USA) and 50 Hz supply. At 50 Hz the motor runs slower, so the flow and head of a direct drive pump are lower than in the 60 Hz data.
The supply frequency in Ukraine is 50 Hz. The series pages state which frequency the figures refer to. We determine the duty point using the manufacturer’s 50 Hz curves.
How these parameters affect the choice is explained in the article “How to select a pump for aggressive and chemically active liquids”.
Steiner Ukraine selects the model and configuration to the technical specification and supplies pumps and spare parts for pumps. We also provide installation, commissioning and service. Prices are quoted on request once the parameters are agreed.
The US company Sundyne, headquartered in Arvada (Colorado). Since 2025 it has been part of Honeywell. Its portfolio includes the ANSIMAG, HMD Kontro, Sunflo and Marelli brands.
A sealless pump has no shaft seal. Torque is transmitted by the magnetic field through the containment shell, so the liquid does not escape and there is no seal to replace.
It is the American Petroleum Institute standard for sealless centrifugal pumps in the petroleum, chemical and gas industries. It has been in force since 2000. HMD Kontro has built pumps to API requirements since 1983.
For pumps to ASME B73.3 and ISO 2858 this is made possible by unified dimensions. The LMV-801S fits in place of the LMV-801 in the same piping. We check each specific replacement against the drawings.
Steiner Ukraine, the official representative of Sundyne: selection, supply, spare parts, installation, commissioning and service.