The Sundyne Direct Drive pump is a vertical single-stage overhung pump in which the impeller turns at motor speed, without a gearbox. The series is built to API 610 (ISO 13709) in OH3 and OH5 designs. It is intended for low flows at medium head in refining, petrochemical and chemical production.
OH3 or OH5: which designs the Sundyne Direct Drive pump is available in
In the OH5 design the pump is rigidly coupled to the motor, which makes the unit more compact. The OH3 design has a separate bearing housing and a flexible coupling, so motors from different manufacturers can be used.
LMV-801, LMV-802 and LMV-806 are available in both designs. LMV-801CS and LMV-803Lr are available in OH3 only.
The pump is installed vertically, directly in the pipeline. This layout takes up less plot space. How in-line pumps work is described in the article “Circulation (In-Line) Pumps: energy-efficient in-line pumping”.
Which Sundyne Direct Drive pump to choose: models and specifications
Flow and head are given for 60 Hz supply according to the manufacturer. At 50 Hz these values are lower; we determine the 50 Hz duty point using Sundyne curves.
| Model |
Design |
Gaskets |
Flow up to, m³/h |
Head up to, m |
Motor up to, kW |
Liquid temperature, °C |
| LMV-801 |
OH3 / OH5 |
single, double, tandem |
86 |
220 |
75 |
−130…+340 |
| LMV-801CS |
OH3 |
API 682 cartridge seal |
86 |
220 |
55 |
−40…+288 |
| LMV-801S |
API 685, close-coupled |
sealless, magnetic coupling |
86 |
220 |
75 |
−40…+205 |
| LMV-802 |
OH3 / OH5 |
single, double, tandem |
34 |
64 |
37 |
−130…+340 |
| LMV-803Lr |
OH3 |
API 682 cartridge seal |
182 |
314 |
298 |
−129…+204 |
| LMV-806 |
OH3 / OH5 |
single, double, tandem |
86 |
232 |
55 |
−40…+175 |
Low NPSH: Barske impeller and LMV-803Lr
LMV-801, 801CS, 801S, 802 and 806 have a Barske impeller, which lowers the required NPSH (NPSHr). These models can be fitted with an inducer; on the LMV-803Lr it is standard.
The LMV-803Lr operates with NPSHr below 3 m across the whole curve. The manufacturer states that this allows the pump to be installed at grade without a pit and reduces the skirt height of a column. The model has oil-mist bearing lubrication and a cryogenic design for NGL fractionation, ethane and LNG.
How low inlet pressure damages the impeller is explained in the article “Pump cavitation: symptoms, causes and how to eliminate it”.
LMV-801S: sealless magnetic drive version
The LMV-801S combines LMV-801 hydraulics with an HMD Kontro magnetic coupling and complies with API 685. It is dimensionally interchangeable with the LMV-801, so it fits existing piping. There is also a version in which only the sealed drive end is replaced, without disconnecting the casing from the piping. The model is designed for clean liquids.
The magnetic coupling principle is described on the page Sundyne. Other sealless models to API 685 are collected on the page HMD Kontro.
Where the Sundyne Direct Drive pump is used
- feed and booster pumps;
- bottoms and reflux pumps;
- wash water supply, condensate transfer;
- acid feed and recirculation, olefin charge;
- depropaniser charge, polypropylene feed;
- sour water.
Industries: refining, natural gas processing, petrochemicals, chemical production, offshore platforms.
Materials and construction
The casing is made of carbon steel or 316 stainless steel; the impeller and inducer are 316 stainless steel. API 610 material classes: S-5, A-7, S-8, and S-9 with Monel for the LMV-801.
Mechanical seal faces are carbon or silicon carbide against tungsten carbide. The series is ATEX certified. The manufacturer states continuous operation of up to 5 years without overhaul.
If higher head is needed at low flow, consider Sundyne Integrally Geared with head up to 1,921 m.
Steiner Ukraine selects the Sundyne Direct Drive pump for the process conditions and supplies spare parts for pumps.
Frequently asked questions
How does OH3 differ from OH5?
In OH5 the pump is rigidly coupled to the motor. OH3 has a separate bearing housing and a flexible coupling, so a motor from another manufacturer can be fitted.
Can an LMV-801 be upgraded without changing the piping?
Yes. The LMV-801 can be fitted with an API 682 cartridge seal (LMV-801CS version) or a magnetic coupling (LMV-801S). The piping and wet end remain unchanged.
Which model suits low suction pressure?
LMV-803Lr: its required NPSH (NPSHr) is below 3 m.
What liquid temperature is permitted?
From −130 to +340 °C for the LMV-801 and LMV-802. Other models have a narrower range, shown in the table.