The Sundyne Integrally Geared pump is a single-stage centrifugal pump with an integral gearbox, built to API 610 (ISO 13709) in the OH6 design. It is designed for low flow and high head: up to 1,921 m at flows up to 91 m³/h, or up to 250 m³/h at lower head. How the gearbox produces high head is explained on the page Sundyne.
LMV or BMP: vertical and horizontal Sundyne Integrally Geared pump
LMV (Line Mounted Vertical) is a vertical pump installed in the pipeline. BMP (Base Mounted Pump) is mounted on a baseplate. In both versions the impeller sits on the high-speed shaft of the gearbox. The vertical version takes up less plot space.
Which Sundyne Integrally Geared pump to choose: models and specifications
| Model |
Flow up to, m³/h |
Head up to, m |
Power up to, kW |
Suction pressure up to, bar |
| LMV-311 |
91 |
1 921 |
150 |
69 |
| LMV-313 |
236 |
546 |
150 |
34,5 |
| LMV-322 |
52 |
915 |
37 |
31 |
| LMV-331 |
91 |
1 400 |
250 |
69 |
| LMV-333 |
227 |
1 280 |
186 |
34,5 |
| BMP-338 |
250 |
854 |
250 |
34,5 |
| LMV-341 |
91 |
1 921 |
315 |
69 |
| LMV-343 |
227 |
915 |
315 |
34,5 |
| LMV-346 |
91 |
1 921 |
315 |
124 |
Pumped liquid temperature for all models is from −130 to +340 °C.
How the hydraulics are matched to the duty point
For each order Sundyne combines the impeller, diffuser and inducer. This places the duty point in the best efficiency zone, and the required NPSH, curve shape and radial load suit the process.
The highest suction pressure in the series is on the LMV-346 — up to 124 bar.
Seals and connections
The pumps operate with single, double or tandem mechanical seals. Seal piping plans API 11, 12, 13, 21, 23, 31, 32, 41, 52, 53, 54, 61, 62 and J are supported.
LMV-311 and LMV-331 have 3″ × 2″ nozzles and ANSI 600# RF flanges, 900# on request. The models are ATEX certified.
On choosing seals and materials for aggressive liquids, see the article “Choosing seals and materials for pumps in aggressive media”.
Where the Sundyne Integrally Geared pump is used
- acid feed and recirculation;
- olefin charge and depropaniser charge;
- polypropylene feed;
- reflux and column overhead;
- sour water, bottoms, wash down.
Industries: refining, petrochemicals, chemical production, power generation, gas production.
When a multistage or simpler pump is needed
If one stage does not give enough head, Sundyne offers HMP multistage pumps with head up to 4,420 m. For head up to 314 m without a gearbox, use Sundyne Direct Drive.
Steiner Ukraine selects the Sundyne Integrally Geared pump for the process conditions and supplies pumps and spare parts.
Frequently asked questions
Why does the pump need an integral gearbox?
The gearbox raises the impeller speed. One impeller delivers the head that a conventional pump needs several stages to reach.
What is the maximum head of the series?
Up to 1,921 m on the LMV-311, LMV-341 and LMV-346.
How does LMV differ from BMP?
LMV is installed vertically in the pipeline, BMP on a baseplate.
What liquid temperature is permitted?
From −130 to +340 °C for all models.