HYGHSPIN screw pump — the base model of the hygienic HYGHSPIN series by Jung Process Systems. It is a stainless steel twin screw pump for food, pharmaceutical and cosmetic products. Flow rate up to 300 m³/h, differential pressure up to 35 bar, viscosity from 0.5 to 1,000,000 mPa·s.
The pump handles aqueous, highly viscous, lumpy, fibrous and gas-laden products as long as they can flow. The same pump delivers the CIP cleaning solution, so no separate cleaning pump is needed.
HYGHSPIN screw pump: technical data
| Size |
Max. flow rate, m³/h |
Max. differential pressure, bar |
Max. solids size, mm |
| HYGHSPIN 50 |
20 |
20 |
16 (25) |
| HYGHSPIN 70 |
40 |
25 |
20 (30) |
| HYGHSPIN 90 |
100 |
30 |
28 (45) |
| HYGHSPIN 105 |
180 |
20 |
35 |
| HYGHSPIN 125 |
300 |
35 |
45 (67) |
| Parameter |
Value |
| Viscosity |
0.5–1,000,000 mPa·s, higher on request |
| Product temperature |
-10…+180 °C, higher upon request |
| Absorption |
NPSHr from 0.5 m, suction lift up to 9 m |
| Cleaning and sterilisation |
CIP in place; SIP with steam or hot water |
| Design |
modular or with bare shaft end |
| Installation |
horizontal, vertical, lateral; INLINE version |
| Drives |
three-phase motors, geared motors, servo motors; optional hygienic stainless steel drives |
| Accession |
DIN or other standards on request |
Which HYGHSPIN design features matter for hygienic production?
- Self-draining. The axial port is located at the lowest point of the casing, so no product remains in the pump.
- Parts machined from solid stock. Product-contact parts are machined from solid material. There is no risk of casting defects.
- Seal flushing. The shaft seal is flushed by the main product flow; there are no dead zones.
- Maintenance in place. The pump is not removed from the line for service. The seals are semi-cartridge units and are replaced as an assembly.
- Gearbox access. Through the inspection opening the gear backlash is adjusted without draining the oil.
- Condition monitoring. Temperature and vibration sensors are available as an option.
Which products does HYGHSPIN handle?
Applications listed by the manufacturer:
- dairy products — quark, butter, ice cream, cream;
- confectionery masses — chocolate and fruit gum masses;
- bakery — raw egg, dough, margarine;
- meat processing — meat masses and sausage meat;
- delicatessen — soups and sauces;
- drinks — juices, syrups, yeast, wine at the must, fermentation and bottling stages;
- cosmetics — lotions, gels, scrubs;
- pharmaceuticals — enzymes, blood plasma;
- pet food — meat masses, glycerine, enzymes.
Which HYGHSPIN version to choose?
| Task |
Implementation |
| Flowable products, differential pressure up to 35 bar |
base HYGHSPIN |
| Large solids and high flow rates, differential pressure up to 6 bar |
HYGHSPIN Extended |
| Differential pressure up to 50 bar, feeding a heat exchanger or filter |
HYGHSPIN Double Flow |
| Thick masses up to 1000 Pa·s that do not flow by gravity |
HYGHSPIN Hopper |
| Non-standard connections, materials, mobile unit |
HYGHSPIN Engineered |
How one pump handles both product and cleaning — see the article “HYGHSPIN twin screw pumps — a 2-in-1 solution” and the overview CIP cleaning of equipment. Materials, elastomers, shaft seals and certificates are common to the whole range — see the Jung Process Systems page.
Selection and service from Steiner Ukraine
To select a HYGHSPIN, we clarify:
- the product, its viscosity at operating temperature and its ability to flow;
- the size and fragility of the pieces to be preserved;
- flow rate and differential pressure at the duty point;
- suction conditions — lift, line length, inlet pressure;
- CIP/SIP mode and connection standard.
Based on these data we define the size, version and seal. Then come supply, service and spare parts. Steiner Ukraine has been operating in the industrial equipment market since 2006.
FAQ about the HYGHSPIN screw pump
Can HYGHSPIN be installed vertically?
Yes. The pump can be installed horizontally, vertically or laterally. An INLINE version is available for straight pipelines.
What is the suction lift of HYGHSPIN?
Up to 9 m. Required NPSHr is from 0.5 m.
Is HYGHSPIN available without a motor?
Yes, in the bare shaft version for connection to an existing drive.
Does HYGHSPIN have to be removed from the line for maintenance?
No. The manufacturer designed the pump for maintenance in place.
Is HYGHSPIN available in an ATEX version?
Yes, as an option. Temperature class T2 to T4 depending on product temperature.