The SAER SD submersible pump is a pump for waste water, drainage and liquids containing solids that operates submerged in a tank. Flow up to 2000 m³/h, head up to 54 m, power up to 132 kW at 50 Hz.
The series is made in Italy. General information on the manufacturer is on the brand page: SAER.
What are the specifications of the SAER SD?
| Parameter |
Value |
| Type |
submersible for waste water |
| Max. flow, 50 Hz |
2000 m³/h |
| Max. head, 50 Hz |
54 m |
| Max. power |
132 kW |
| Impeller |
vortex, open, closed or helical |
| Casing |
cast iron |
Which impeller suits the SAER SD submersible pump?
The series is available with four impeller types: vortex, open, closed and helical. We choose the impeller from the effluent composition (solids content and size, presence of fibres) and the efficiency requirement.
A wide range of accessories is available, including a detector that monitors for water in the oil chamber.
Which versions and accessories are available?
- support foot for free-standing installation;
- automatic coupling system;
- guide tubes and lifting chains on request;
- control panels, floats and level sensors, cables, SAER water detector.
Where are SAER SD pumps used?
Sewage lifting stations, rainwater and groundwater drainage, slurry transfer in agriculture and process sludge in industry, treatment plants, liquids containing solids, and clean water with small amounts of particles.
How to select a SAER SD pump?
We need the flow and head at the duty point, the effluent composition, solids size and content, tank levels and the installation method. For installation in a dry room we consider the series SAER NCA.
Steiner Ukraine selects the size, impeller and accessories, supplies the pump and spare parts and carries out installation and service. Other series are listed under drainage pumps.
Frequently asked questions
Which impellers are available for the SAER SD?
Vortex, open, closed and helical.
What is the oil-chamber water detector for?
It monitors for the presence of water in the pump's oil chamber.
How does the SD differ from the NCA?
The SD operates submerged in the tank. The NCA is installed in a dry room outside the tank.