Packo HyLine pump — these are two lobe series from the same family: HP and LH. Both are designed for viscosities up to 1,000,000 cP, temperatures up to 140 °C, and differential pressures up to 15 bar. The difference between them lies in their size: the HP covers flow rates up to 41 m³/h, while the LH covers up to 108.5 m³/h.
Steiner Ukraine supplies Packo equipment in Ukraine: process-specific selection, delivery, service, and spare parts.
HP and LH are lobe pumps. The manufacturer describes them identically for both series: pumps with a long history of application in almost all food and hygienic industries.
Product contact parts are made of 316L stainless steel in both series.
The technical documentation of the manufacturer common to HP and LH is named HyLine. Hence the dual designation of the series in the catalogue.
Other equipment from this manufacturer can be found on the page Verder – Packo.
The technological limits for both series are the same. They differ in size, rotation speed and the list of conformity documents.
| Parameter | HP | LH |
|---|---|---|
| Maximum flow rate | 41 m³/h | 1809 l/min (≈108.5 m³/h) |
| Maximum differential pressure | 15 bar | 15 bar |
| Maximum viscosity | 1,000,000 cP | 1,000,000 cP |
| Maximum temperature | 140 °C | 140 °C |
| Size of the pipes | 19–125 mm | 75–125 mm |
| Maximum engine speed | 1000 rpm | 680 rpm |
| Product contact material | 316L | 316L |
| Compliance documents | EC 1935/2004, FDA, USP, ATEX | EC 1935/2004, FDA, 3-A |
Rule of thumb. A required flow rate of up to 41 m³/h or a small connection from 19 mm means HP. A requirement of over 41 m³/h means LH. Explosion-proof design required — ATEX is only declared for HP. A 3-A certificate required — it is only declared for LH.
LH is the largest lobe pump in the Packo catalogue. The ZL and ZLC series are limited to 100 m³/h.
| Parameter | Value |
|---|---|
| Type | rotary lobe pump |
| Series | HP and LH |
| Feed range | up to 41 m³/h (HP), up to 108.5 m³/h (LH) |
| Maximum differential pressure | 15 bar |
| Maximum viscosity | 1,000,000 cP |
| Maximum temperature | 140 °C |
| Size of the pipes | 19–125 mm |
| Maximum engine speed | 1000 rpm (HP), 680 rpm (LH) |
| Details regarding the product | 316L stainless steel |
| Industries by manufacturer description | food, dairy, beverages, pharmaceuticals |
A viscosity of 1,000,000 cP is the upper limit of the entire Packo lobe pump range. For comparison, the ZW wine series is limited to 1,000 cP, which is a thousand times lower.
A positive displacement pump must not be started against a closed valve. The flow rate does not drop with an increase in backpressure, and the pressure rises until the equipment is damaged.
The manufacturer names four sectors: the food, dairy, beverages, and pharmaceuticals.
The technical limits of the series determine what actually makes sense to pump.
| Product property | Why HyLine is suitable |
|---|---|
| High viscosity, up to 1,000,000 cP | top of the Packo cam profile range |
| Hot feed, up to 140 °C | top of the Packo cam profile range |
| Shear sensitivity | bulk transfer without product acceleration |
| Solid inclusions | the product does not get squeezed between the paddles |
| Dosage requirement | feed rate is proportional to the revolutions |
Products with a viscosity below 1,000 cP and without inclusions are usually cheaper to pump with a centrifugal pump.
The lists in the two series are different. This is important for the tender documentation.
| Document | HP | LH |
|---|---|---|
| EC 1935/2004 (materials in contact with food) | yes | yes |
| FDA | yes | yes |
| USP | yes | not stated |
| 3-A | not stated | yes |
| ATEX | yes | not stated |
The manufacturer does not claim EHEDG for the HP and LH series. This designation does not appear on any of the four verified series pages. If EHEDG is required in your project, this must be confirmed in writing with Packo before submitting a proposal.
The LH operates at a maximum of 680 rpm, and the HP at 1,000 rpm. By comparison, a centrifugal pump typically operates at 1,450 or 2,900 rpm.
The reason lies in the very principle. A positive displacement pump moves a fixed volume per revolution. To deliver 108 m³/h, the LH uses large chambers rather than high speed.
Practical consequence two. The first is a smaller shift in the product: it does not accelerate and does not hit the walls. The second is lower wear: the friction pair travels a shorter distance per hour of operation.
For viscous products, low speeds are also mandatory. The thick mass does not manage to fill the chamber at high speed, and the pump loses its priming.
Packo has nine lobe pump series. HyLine is at the top of these in terms of viscosity and temperature.
| Task | The series |
|---|---|
| Viscosity up to 1,000,000 cP, temperature up to 140 °C, flow rate up to 41 m³/h | HP |
| Same, delivery up to 108.5 m³/h | LH |
| Pressure over 15 bar | ZL or ZLC (up to 20 bar) |
| Winemaking, whole berry fraction | ZW |
| Loading and unloading of road tankers, hydraulic motor drive | LT |
| Low flow rate, up to 4 m³/h | 55 |
| Data | Why |
|---|---|
| Product and viscosity at operating temperature | choice between HP and LH, selection of size/type size |
| Flow rate, m³/h | FSH up to 41, LH up to 108.5 |
| Backpressure in the line | pressure check up to 15 bar |
| Product temperature | check up to 140 °C |
| Size and connection type | 19–125 mm |
| Presence of solid inclusions and their size | determines the rotor configuration |
| Hazardous area classification | ATEX statements for HP |
| Need for a 3-A certificate | applications for LH |
| CIP wash mode | temperature and means |
What does HyLine mean?
This is the collective title of the manufacturer's technical documentation for two cam series — HP and LH.
What is the maximum flow rate?
HP — 41 m³/h. LH — 1809 l/min, i.e. about 108.5 m³/h. LH is the largest lobe pump in the Packo catalogue.
What is the maximum pressure?
15 bar differential pressure in both series. For higher pressures, Packo has the ZL and ZLC series up to 20 bar.
What is the maximum viscosity?
1,000,000 cP. This is the upper limit of the entire Packo lobe pump range.
What is the maximum temperature?
140 °C in both series.
What are the pipe sizes?
HP — from 19 to 125 mm. LH — from 75 to 125 mm.
Is there an ATEX version available?
ATEX manufacturer declares for the HP series. For LH, ATEX is not declared in verified sources.
Is there a 3-A certificate?
3-A is declared by the manufacturer for the LH series. For HP, on the other hand, USP is declared.
Is there an EHEDG certificate?
For the HP and LH series, the manufacturer does not declare EHEDG compliance. This requires written confirmation if it is needed for the project.
What grade of steel are the parts in contact with the product made from?
316L stainless steel in both series.
Enquiry for selection and price via ContactsOther equipment from the manufacturer — Verder – PackoRelated sections: Pumps for food production, Industrial pumps, Spare parts.
universal for a wide range of production processes.