The SAER TMV multistage pump is a vertical centrifugal pump for duties that require high pressure where floor space is limited. Flow up to 300 m³/h, head up to 403 m, power up to 250 kW at 50 Hz.
The operating principle of multistage pumps and the materials SAER uses are described on the brand page: SAER.
What are the specifications of the SAER TMV?
| Parameter |
Value |
| Type |
vertical multistage centrifugal |
| Max. flow, 50 Hz |
300 m³/h |
| Max. head, 50 Hz |
403 m |
| Max. power |
250 kW |
| Materials |
cast iron, ductile iron, stainless steel, Super Duplex |
| Fluid temperature |
version up to 120 °C on request |
How does the TMV differ from SAER horizontal pumps?
The vertical layout takes up less floor space than the horizontal TM/TMB. TMV covers up to 300 m³/h and 403 m, while TM/TMB covers higher flows and heads.
The pump is available with a range of inlet and outlet configurations. The manufacturer recommends the Super Duplex version for desalination plants.
Which versions and accessories are available?
- versions for specific liquids and operating conditions;
- version with ACS certification for potable water;
- version for liquids up to 120 °C on request;
- ANSI flange drilling on request;
- PAT version, pump as turbine;
- vibration sensors, PT100 bearing sensors.
Where is the SAER TMV multistage pump used?
Booster stations, cooling and heating plants, artificial snowmaking, irrigation, washing systems, boiler feed, condensate extraction, water supply and desalination plants.
How to select a SAER TMV pump?
We need the flow and head at the duty point, the inlet pressure, the liquid composition and temperature, the available floor space and the supply data. If space is not limited or more than 300 m³/h is required, we consider TM/TMB.
Steiner Ukraine selects the model, number of stages and material, supplies the pump and spare parts and carries out installation and service. Other series are listed under multistage pumps.
Frequently asked questions
What head does the SAER TMV deliver?
Up to 403 m at flows up to 300 m³/h, 50 Hz.
Is there a TMV for potable water?
Yes, a version with ACS certification for potable water is available.
What is the PAT version?
It is a pump operating as a turbine: the liquid flow turns the shaft and the unit generates electricity.