The SAER MK multistage pump is a compact vertical non-self-priming electric pump. Flow up to 110 m³/h, head up to 394 m, power up to 55 kW at 50 Hz.
The operating principle of multistage pumps and the materials SAER uses are described on the brand page: SAER.
What are the specifications of the SAER MK?
| Parameter |
Value |
| Type |
vertical multistage, non-self-priming |
| Max. flow, 50 Hz |
110 m³/h |
| Max. head, 50 Hz |
394 m |
| Max. power |
55 kW |
| Materials |
cast iron, stainless steel |
| Version |
MK with separate motor, MKM monobloc |
What are the design features of the MK?
The pump has an integrated bearing that takes the axial thrust. This allows the MK to be coupled with standard motors without thrust bearings and extends pump service life.
The series is available in various material and motor configurations. The vertical layout minimises the footprint.
How does the MK differ from other SAER vertical pumps?
The MK sits in the middle of the SAER vertical range. For small flows up to 18 m³/h there is the monobloc SAER MBSH made of stainless steel. For flows above 110 m³/h we consider SAER TMV with flows up to 300 m³/h and power up to 250 kW.
Which versions and accessories are available?
- MKM monobloc version;
- ANSI flange drilling on request;
- motor-mounted variable frequency drive up to 18.5 kW;
- control panels.
Where is the SAER MK multistage pump used?
Booster stations with or without a pressure tank, irrigation systems, water supply for buildings and industrial sites, and process lines that require high pressure.
How to select a SAER MK pump?
We need the flow and head at the duty point, the inlet pressure, the liquid composition and temperature, the supply data and the control method. For variable demand we consider a package with a variable frequency drive.
Steiner Ukraine selects the model, number of stages and motor, supplies the pump and spare parts and carries out installation and service. Other series are listed under multistage pumps.
Frequently asked questions
Does the SAER MK need a motor with a thrust bearing?
No. The axial thrust is taken by the pump's integrated bearing, so a standard motor is suitable.
Is there a monobloc version?
Yes, the MKM.
Can the MK be fitted with a variable frequency drive?
Yes, a motor-mounted drive is available for ratings up to 18.5 kW.